Article number |
6ES7222-1BF32-0XB0 |
6ES7222-1BH32-0XB0 |
6ES7222-1BH32-1XB0 |
6ES7222-1HF32-0XB0 |
6ES7222-1HH32-0XB0 |
6ES7222-1XF32-0XB0 |
|
Digital Output SM1222, 8 DO, 24V DC |
Digital Output SM1222, 16 DO, 24V DC |
Digital Output SM1222, 16DO, 24V DC sink |
Digital Output SM 1222, 8 DO, Relay |
Digital Output SM1222, 16 DO, Relay |
Digital Output SM 1222, 8 DO, Changeover |
General information |
|
|
|
|
|
|
Product type designation |
SM 1222, DQ 8x24 V DC/0.5 A |
SM 1222, DQ 16x24 V DC/0.5 A |
SM 1222, DO 16x 24 V DC/0.5 A Sink |
SM 1222, DQ 8x relay/2 A |
SM 1222, DQ 16x relay/2 A |
SM 1222, DQ 8x relay/2 A |
Supply voltage |
|
|
|
|
|
|
permissible range, lower limit (DC) |
20.4 V |
20.4 V |
20.4 V |
20.4 V |
20.4 V |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
28.8 V |
28.8 V |
28.8 V |
28.8 V |
28.8 V |
Input current |
|
|
|
|
|
|
from backplane bus 5 V DC, max. |
120 mA |
140 mA |
140 mA |
120 mA |
135 mA |
140 mA |
Digital outputs |
|
|
|
|
|
|
● from load voltage L+, max. |
|
|
|
11 mA/relay coil |
11 mA/relay coil |
16.7 mA/relay coil |
Power loss |
|
|
|
|
|
|
Power loss, typ. |
1.5 W |
2.5 W |
2.5 W |
4.5 W |
8.5 W |
5 W |
Digital outputs |
|
|
|
|
|
|
Number of digital outputs |
8 |
16 |
16 |
8 |
16 |
8 |
● in groups of |
1 |
1 |
1 |
2 |
1 |
1 |
Current-sinking |
|
|
Yes |
|
|
|
Short-circuit protection |
No; to be provided externally |
No; to be provided externally |
No; to be provided externally |
No; to be provided externally |
No; to be provided externally |
No; to be provided externally |
Limitation of inductive shutdown voltage to |
typ. (L+) -48 V |
typ. (L+) -48 V |
Typ 45 V |
|
|
|
Switching capacity of the outputs |
|
|
|
|
|
|
● with resistive load, max. |
0.5 A |
0.5 A |
0.5 A |
2 A |
2 A |
2 A |
● on lamp load, max. |
5 W |
5 W |
5 W |
30 W with DC, 200 W with AC |
30 W with DC, 200 W with AC |
30 W with DC, 200 W with AC |
Output voltage |
|
|
|
|
|
|
● Rated value (DC) |
24 V |
24 V |
24 V |
5 V DC to 30 V DC |
5 V DC to 30 V DC |
5 V DC to 30 V DC |
● Rated value (AC) |
|
|
|
5 V AC to 250 V AC |
5 V AC to 250 V AC |
5 V AC to 250 V AC |
● for signal "0", max. |
0.1 V; with 10 kOhm load |
0.1 V; with 10 kOhm load |
L+ minus 0.75 V DC with 10k Load |
|
|
|
● for signal "1", min. |
20 V DC |
20 V DC |
0,5 V |
|
|
|
Output current |
|
|
|
|
|
|
● for signal "1" rated value |
0.5 A |
0.5 A |
0.5 A |
2 A |
2 A |
2 A |
● for signal "0" residual current, max. |
10 µA |
10 µA |
75 µA |
|
|
|
Output delay with resistive load |
|
|
|
|
|
|
● "0" to "1", max. |
50 µs |
50 µs |
20 µs |
10 ms |
10 ms |
10 ms |
● "1" to "0", max. |
200 µs |
200 µs |
350 µs |
10 ms |
10 ms |
10 ms |
Total current of the outputs (per group) |
|
|
|
|
|
|
horizontal installation |
|
|
|
|
|
|
— up to 50 °C, max. |
4 A; Current per mass |
8 A; Current per mass |
8 A; Current per mass |
10 A; Current per mass |
10 A; Current per mass |
2 A; Current per mass |
Relay outputs |
|
|
|
|
|
|
● Number of relay outputs |
|
|
|
8 |
16 |
8 |
● Rated supply voltage of relay coil L+ (DC) |
|
|
|
24 V |
24 V |
24 V |
● Number of operating cycles, max. |
|
|
|
mechanically 10 million, at rated load voltage 100 000 |
mechanically 10 million, at rated load voltage 100 000 |
mechanically 10 million, at rated load voltage 100 000 |
Switching capacity of contacts |
|
|
|
|
|
|
— with inductive load, max. |
0.5 A |
0.5 A |
0.5 A |
2 A |
2 A |
2 A |
— on lamp load, max. |
5 W |
5 W |
5 W |
30 W with DC, 200 W with AC |
30 W with DC, 200 W with AC |
30 W with DC, 200 W with AC |
— with resistive load, max. |
0.5 A |
0.5 A |
0.5 A |
2 A |
2 A |
2 A |
Cable length |
|
|
|
|
|
|
● shielded, max. |
500 m |
500 m |
500 m |
500 m |
500 m |
500 m |
● unshielded, max. |
150 m |
150 m |
150 m |
150 m |
150 m |
150 m |
Interrupts/diagnostics/status information |
|
|
|
|
|
|
Alarms |
|
|
|
|
|
|
● Diagnostic alarm |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Diagnostics indication LED |
|
|
|
|
|
|
● for status of the outputs |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Potential separation |
|
|
|
|
|
|
Potential separation digital outputs |
|
|
|
|
|
|
● between the channels |
|
|
|
Relays |
Relays |
Relays |
● between the channels, in groups of |
1 |
1 |
1 |
2 |
4 |
1 |
● between the channels and backplane bus |
500 V AC |
500 V AC |
500 V AC |
1 500 V AC for 1 minute |
1 500 V AC for 1 minute |
1 500 V AC for 1 minute |
Permissible potential difference |
|
|
|
|
|
|
between different circuits |
|
|
|
750 V AC for 1 minute |
750 V AC for 1 minute |
750 V AC for 1 minute |
Degree and class of protection |
|
|
|
|
|
|
IP degree of protection |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |