MOXA ICF-1150I-M-SC Serial-to-Fiber Converter
3-way communication: RS-232, RS-422/485, and fiber
Rotary switch to change the pull high/low resistor value
Extends RS-232/422/485 transmission up to 40 km with single-mode or 5 km with multi-mode
-40 to 85°C wide-temperature range models available
C1D2, ATEX, and IECEx certified for harsh industrial environments
Serial Interface
No. of Ports | 2 |
Serial Standards | RS-232RS-422RS-485 |
Baudrate | 50 bps to 921.6 kbps (supports non-standard baudrates) |
Flow Control | ADDC (automatic data direction control) for RS-485 |
Connector | DB9 female for RS-232 interface5-pin terminal block for RS-422/485 interfaceFiber ports for RS-232/422/485 interface |
Isolation | 2 kV (I models) |
Serial Signals
RS-232 | TxD, RxD, GND |
RS-422 | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w | Data+, Data-, GND |
Power Parameters
Input Current | ICF-1150 Series: 264 mA@12to 48 VDC ICF-1150I Series: 300 mA@12to 48 VDC |
Input Voltage | 12to48 VDC |
No. of Power Inputs | 1 |
Overload Current Protection | Supported |
Power Connector | Terminal block |
Power Consumption | ICF-1150 Series: 264 mA@12to 48 VDC ICF-1150I Series: 300 mA@12to 48 VDC |
Physical Characteristics
Housing | Metal |
IP Rating | IP30 |
Dimensions | 30.3 x70 x115 mm (1.19x 2.76 x 4.53 in) |
Weight | 330 g (0.73 lb) |
Installation | DIN-rail mounting |
Environmental Limits
Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature (package included) | -40 to 85°C (-40 to185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
MOXA ICF-1150I-M-SC Available Models
Model Name | Isolation | Operating Temp. | Fiber Module Type | IECEx Supported |
ICF-1150-M-ST | - | 0 to 60°C | Multi-mode ST | - |
ICF-1150-M-SC | - | 0 to 60°C | Multi-mode SC | - |
ICF-1150-S-ST | - | 0 to 60°C | Single-mode ST | - |
ICF-1150-S-SC | - | 0 to 60°C | Single-mode SC | - |
ICF-1150-M-ST-T | - | -40 to 85°C | Multi-mode ST | - |
ICF-1150-M-SC-T | - | -40 to 85°C | Multi-mode SC | - |
ICF-1150-S-ST-T | - | -40 to 85°C | Single-mode ST | - |
ICF-1150-S-SC-T | - | -40 to 85°C | Single-mode SC | - |
ICF-1150I-M-ST | 2kV | 0 to 60°C | Multi-mode ST | - |
ICF-1150I-M-SC | 2kV | 0 to 60°C | Multi-mode SC | - |
ICF-1150I-S-ST | 2kV | 0 to 60°C | Single-mode ST | - |
ICF-1150I-S-SC | 2kV | 0 to 60°C | Single-mode SC | - |
ICF-1150I-M-ST-T | 2kV | -40 to 85°C | Multi-mode ST | - |
ICF-1150I-M-SC-T | 2kV | -40 to 85°C | Multi-mode SC | - |
ICF-1150I-S-ST-T | 2kV | -40 to 85°C | Single-mode ST | - |
ICF-1150I-S-SC-T | 2kV | -40 to 85°C | Single-mode SC | - |
ICF-1150-M-ST-IEX | - | 0to 60°C | Multi-mode ST | / |
ICF-1150-M-SC-IEX | - | 0to 60°C | Multi-mode SC | / |
ICF-1150-S-ST-IEX | - | 0to 60°C | Single-mode ST | / |
ICF-1150-S-SC-IEX | - | 0to 60°C | Single-mode SC | / |
ICF-1150-M-ST-T-IEX | - | -40 to 85°C | Multi-mode ST | / |
ICF-1150-M-SC-T-IEX | - | -40 to 85°C | Multi-mode SC | / |
ICF-1150-S-ST-T-IEX | - | -40 to 85°C | Single-mode ST | / |
ICF-1150-S-SC-T-IEX | - | -40 to 85°C | Single-mode SC | / |
ICF-1150I-M-ST-IEX | 2kV | 0to 60°C | Multi-mode ST | / |
ICF-1150I-M-SC-IEX | 2kV | 0to 60°C | Multi-mode SC | / |
ICF-1150I-S-ST-IEX | 2kV | 0to 60°C | Single-mode ST | / |
ICF-1150I-S-SC-IEX | 2kV | 0to 60°C | Single-mode SC | / |
ICF-1150I-M-ST-T-IEX | 2kV | -40 to 85°C | Multi-mode ST | / |
ICF-1150I-M-SC-T-IEX | 2kV | -40 to 85°C | Multi-mode SC | / |
ICF-1150I-S-ST-T-IEX | 2kV | -40 to 85°C | Single-mode ST | / |
ICF-1150I-S-SC-T-IEX | 2kV | -40 to 85°C | Single-mode SC | / |